Save and perfectly matched products for drive enginnering

By using modern frequency converters, the drive technology becomes more and more energy efficient. Due to the frequency converters, these powerful controllers produce strong electrical noise on the motor cable that adversely affect the engine and other consumers.

To ensure reliable and durable operation of all drive components, the electrical noise must be reduced as far as possible. Basically, many different factors such as volage rise (dv / dt), fault and surge currents, EMC behavior, harmonics, etc. must be observed.

Targeted measurements and perfectly matched products

Since these physical effects often occur in combination, targeted and well-coordinated measurements additional components are important. For the most diverse applications REO always offers the best electronic, inductive and resistive components.

Line chokes, EMC filter, DC reactors, chokes or sinusoidal and dv / dt filters are just a few examples of products, by which REO guarantees a safe and trouble-free operation in drive technology.

Water-cooled components for high performance or fully encapsulated systems with high protection classes are examples of our innovative strength. Many years of experience and the highest quality standards make REO a strong partner.

Customized solutions

In addition to a wide range of standard products we develop, of course, customized solutions - Just talk to us!

  • CNW 901

    Single-phase mains choke 4%

    CNW 901
    • Nominal Voltage: 250 V
    • Rated current: 2 - 100 A
    • Inductance: 0.29 - 14.5 mH

    Power Noise Reduction - save up to 20% energy costs. A mains choker relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced much. By using a mains choke the inverter electronics and DC-capacitors will be protected.

    Starting currents and current peaks are reduced up to 60%. Mains chokes help to comply with international power quality standards IEEE 519 or EN 61000-3-2.

    • Rated voltage: U ≤ 250 V 
    • Short circuit: Uk 4% (230VAC/50Hz, INnomin)
    • Frequency: 50/60 Hz
    • According to: EN 60289 / EN 61558
    • Test voltage: L-PE 2,500 V, DC 1min
    • Insulation class: T40/F
    • Protection rating: IP00
    • Climatic Category: DIN IEC 60068-1
    • Overload: 1.5 x INnomin 1 min / h
    • Design: mounted on foot print
       

    Typical Applications

    • Drive systems for motor drives:
      • Mechanical engineering pump
      • Conveyor technology
      • Ventilation and air conditioning
      • Robotics
    • Automation technology
      • Power supplies


  • CNW 903

    Three-phase line reactor 4% Uk

    CNW 903
    • Nominal Voltage: 3 x 500 V
    • Rated current: 3-1200 A
    • Inductance: 9.800-0.024 mH

    Power Noise Reduction - save up to 20% energy costs. A mains choker relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By using a mains choke the inverter electronics and DC-capacitors will be protected.

    Starting currents and current peaks are reduced up to 60%. Mains chokes help to comply with international power quality standards IEEE 519 or EN 61000-3-2.

    • Rated voltage: U ≤ 3 x 500 V 
    • Short circuit: Uk 4% (400VAC/50Hz, INenn)
    • Frequency: 50/60 Hz
    • According to: EN 60289 / EN 61558
    • Test voltage: L-L 2,500 V, DC 1min; L-PE 2,500 V, DC 1min
    • Insulation class: T40/F
    • Protection rating: IP00
    • Climatic category: DIN IEC 60068-1
    • Overload: 1.5 x INenn 1 min / h
    • Design: mounted on footprint

     

    Typical applications

    • Drive systems for motor drives:
      • Mechanical engineering
      • Elevators / escalators
      • Pipes
      • Conveyor technology
      • Ventilation and air conditioning
      • Robotics
      • Automation technology
    • Power supplies
    • Wind turbines


  • REOHM R 151

    Load- and discharge resistor, max. continuous power: 300 W

    BW 156
    • Resistance values: 1.1 - 2000 Ohm
    • Continuous power: 50 - 300 W
    • max. operating voltage: 900 V

    The charging resistor R 151 is a current limiting resistor for the charging and discharging of capacitors and limits, for example, the current flowing into the intermediate circuit capacitor inrush current. They are available as a braking resistor (BW Series) or as a charging resistor (Series R).

    Typical Applications: 

    • Drive Technology
    • Wind power, solar energies
    • Railway engineering
    • Electromobility

     

    Available as UL version

    The profile resistors REOhm 151 are also UL-certified and have a power of 50 W up to 30 W (also as a combination).

    Maximum energy with minimum space

    • In case of failure of resistor, this will become highly resistive.
    • Suitable for IP20 - IP54 applications
    • Test voltage: 2.5 kV AC (at 900 V rated voltage)

    Optional

    • With temperature switch
    • Cover for protection against high surface temperatures


  • CNW 9022

    Line reactor with surge protection

    CNW 9022
    • Nominal Voltage: 230 V (DC) V
    • Rated current: 10 A / 16 A
    • Inductance: 2 x 1.46 +/- 10% / 2 x 0.92 +/-10% mH

    The CNW 9022 is designed to accommodate minimal spatial requirements, includes integrated surge protection.


    CNW 9022 line reactor with integrated surge protection smooths current peaks in controller input power, helping to maintain consistent product movement and extend equipment life. This filter has been specifically developed for use with vibratory feeder controllers to reduce stress on internal components and the power supply feeding the controller.


     


    Typical applications



    • use with vibratory feeder controllers to reduce stress on internal components and the power supply feeding the controller.


     

  • REOHM BW 151 (UL)

    Braking resistor, max. continous power: 300 W

    REOHM BW 151 (UL)
    • Resistance values: 10 - 300 Ohm
    • Continuous power: 50 - 250 W
    • max. operating voltage: 900 V

    Braking resistor for drives with frequency converters
    of low to medium power or as a charging resistor.
    Mounting close to the frequency inverter.



    • protection class IP 20 / IP 54

    • higher protection classes on request

    • test voltage 2.5 kV AC

    • other ratings and mounting dimensions on request

  • REOHM BW 151

    Braking resistor, max. continous power: 300 W

    REOHM BW 151
    • Resistance values: 10 - 300 Ohm
    • Continuous power: 50 - 250 W
    • max. operating voltage: 900 V

    Braking resistor for drives with frequency converters
    of low to medium power or as a charging resistor.
    Mounting close to the frequency inverter.



    • protection class IP 20 / IP 54

    • higher protection classes on request

    • test voltage 2.5 kV AC

    • other ratings and mounting dimensions on request

  1. Page:
  2. 1
  3. 2
  4. 3

Downloads

  • Download
    Industrial Converter Solutions - Drives
    pdf 4.00 KB

    Industrial Converter Solutions - Drives

    REOunity - System Solutions for Variable Speed Drives
    Download
  • Download
    Protection Ratings
    pdf 4.00 KB

    Protection Ratings

    Discover our brochure about high protection ratings!
    Download
  • Download
    Performance wiith sinusoidal filters
    pdf 4.00 KB

    Performance wiith sinusoidal filters

    Save money with unshielded cables
    Download
  • Download
    Line Reactor CNW 9022
    pdf 4.00 KB

    Line Reactor CNW 9022

    CNW 9022 line reactor with integrated surge protection
    Download
  • Download
    EMC-Filter Product catalogue
    pdf 4.00 KB

    EMC-Filter Product catalogue

    Product catalogue
    Download
  • Download
    Air-cooled Resistors catalogue
    pdf 4.00 KB

    Air-cooled Resistors catalogue

    Product catalogue for Air-cooled Resistors
    Download
  • Download
    Current and voltage sensors Product catalogue
    pdf 4.00 KB

    Current and voltage sensors Product catalogue

    REO current and voltage sensors, Product catalogue
    Download
  • Download
    Liquid-cooled braking resistors
    pdf 4.00 KB

    Liquid-cooled braking resistors

    REO Braking- and charging resistors
    Download
  • Download
    Chokes Product catalog
    pdf 4.00 KB

    Chokes Product catalog

    Chokes Product catalog
    Download
  • Download
    Chokes Product catalog
    image 4.00 KB

    Chokes Product catalog

    REO Chokes Product catalog
    Download
  • Download
    Toroidal core transformers catalogue
    pdf 4.00 KB

    Toroidal core transformers catalogue

    Product catalogue toroidal core transformers
    Download
  • Download
    Liquid cooled systems catalog
    pdf 4.00 KB

    Liquid cooled systems catalog

    Product catalog for liquid cooled systems
    Download
  • Download
    Braking resistors Overview
    pdf 4.00 KB

    Braking resistors Overview

    REO Braking- and charging resistors The product range at a glance
    Download
  • Download
    Liquid-cooled components
    pdf 4.00 KB

    Liquid-cooled components

    Liquid-cooled components The product range at a glance
    Download
  • Download
    REO chokes with high protection ratings
    pdf 4.00 KB

    REO chokes with high protection ratings

    REO chokes with high protection ratings Fully encapsulated REO chokes
    Download
  • Download
    REOWAVEpassive
    pdf 4.00 KB

    REOWAVEpassive

    The new generation of harmonic filters
    Download
  • Download
    Directly cooled surge current choke
    pdf 4.00 KB

    Directly cooled surge current choke

    Directly cooled surge current choke More power, lower costs
    Download
  • Download
    PLC- and circuit filter
    pdf 4.00 KB

    PLC- and circuit filter

    for use with Powerline Communication (PLC) faults
    Download
  • Download
    REOHM BW D 330
    pdf 4.00 KB

    REOHM BW D 330

    Resistance for hybrid and electric drives for commercial vehicles
    Download
  • Download
    REO Regenerative Line Reactors CNW 953
    pdf 4.00 KB

    REO Regenerative Line Reactors CNW 953

    REO Regenerative Line Reactors CNW 953 for the use with regenerative converters
    Download
  • Download
    Operating instructions
    pdf 4.00 KB

    Operating instructions

    Operating instructions - REO - Mains chokes, DC chokes Motor chokes, sine-wave filters, du/dt chokes
    Download