us
IndustrialConverter Solutions - Drives

IndustrialConverter Solutions - Drives

Featured news

Show All

www.REOHM.de

• Compact dimensions

• Low weight

• Very high power density

• Use of power loss for heat
   management

Read more

Save and perfectly matched products for drive enginnering

By using modern frequency converters, the drive technology becomes more and more energy efficient. Due to the frequency converters, these powerful controllers produce strong electrical noise on the motor cable that adversely affect the engine and other consumers.

To ensure reliable and durable operation of all drive components, the electrical noise must be reduced as far as possible. Basically, many different factors such as volage rise (dv / dt), fault and surge currents, EMC behavior, harmonics, etc. must be observed.

Targeted measurements and perfectly matched products

Since these physical effects often occur in combination, targeted and well-coordinated measurements additional components are important. For the most diverse applications REO always offers the best electronic, inductive and resistive components.

Line chokes, EMC filter, DC reactors, chokes or sinusoidal and dv / dt filters are just a few examples of products, by which REO guarantees a safe and trouble-free operation in drive technology.

Water-cooled components for high performance or fully encapsulated systems with high protection classes are examples of our innovative strength. Many years of experience and the highest quality standards make REO a strong partner.

Customized solutions

In addition to a wide range of standard products we develop, of course, customized solutions - Just talk to us!

  • CNW 901

    Single-phase mains choke 4%

    CNW 901
    • Nominal Voltage: 250 V
    • Rated current: 2 - 100 A
    • Inductance: 0.29 - 14.5 mH

    Power Noise Reduction - save up to 20% energy costs. A mains choker relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced much. By using a mains choke the inverter electronics and DC-capacitors will be protected.

    Starting currents and current peaks are reduced up to 60%. Mains chokes help to comply with international power quality standards IEEE 519 or EN 61000-3-2.

    • Rated voltage: U ≤ 250 V 
    • Short circuit: Uk 4% (230VAC/50Hz, INnomin)
    • Frequency: 50/60 Hz
    • According to: EN 60289 / EN 61558
    • Test voltage: L-PE 2,500 V, DC 1min
    • Insulation class: T40/F
    • Protection rating: IP00
    • Climatic Category: DIN IEC 60068-1
    • Overload: 1.5 x INnomin 1 min / h
    • Design: mounted on foot print
       

    Typical Applications

    • Drive systems for motor drives:
      • Mechanical engineering pump
      • Conveyor technology
      • Ventilation and air conditioning
      • Robotics
    • Automation technology
      • Power supplies


  • CNW 903

    Three-phase line reactor 4% Uk

    CNW 903
    • Nominal Voltage: 3 x 500 V
    • Rated current: 3-1200 A
    • Inductance: 9.800-0.024 mH

    Power Noise Reduction - save up to 20% energy costs. A mains choker relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By using a mains choke the inverter electronics and DC-capacitors will be protected.

    Starting currents and current peaks are reduced up to 60%. Mains chokes help to comply with international power quality standards IEEE 519 or EN 61000-3-2.

    • Rated voltage: U ≤ 3 x 500 V 
    • Short circuit: Uk 4% (400VAC/50Hz, INenn)
    • Frequency: 50/60 Hz
    • According to: EN 60289 / EN 61558
    • Test voltage: L-L 2,500 V, DC 1min; L-PE 2,500 V, DC 1min
    • Insulation class: T40/F
    • Protection rating: IP00
    • Climatic category: DIN IEC 60068-1
    • Overload: 1.5 x INenn 1 min / h
    • Design: mounted on footprint

     

    Typical applications

    • Drive systems for motor drives:
      • Mechanical engineering
      • Elevators / escalators
      • Pipes
      • Conveyor technology
      • Ventilation and air conditioning
      • Robotics
      • Automation technology
    • Power supplies
    • Wind turbines


  • CNW 9022

    Line reactor with surge protection

    CNW 9022
    • Nominal Voltage:  / 230 (VAC) / 230 (VAC) V
    • Rated current: 6 A / 10 A / 16 A
    • Inductance: 2 x 2.44 mH / 2 x 1.46 mH +/- 10% / 2 x 0.92 +/-10% mH

    The CNW 9022 is designed to accommodate minimal spatial requirements, includes integrated surge protection.


    CNW 9022 line reactor with integrated surge protection smooths current peaks in controller input power, helping to maintain consistent product movement and extend equipment life. This filter has been specifically developed for use with vibratory feeder controllers to reduce stress on internal components and the power supply feeding the controller.


     


    Typical applications



    • use with vibratory feeder controllers to reduce stress on internal components and the power supply feeding the controller.


     

  • REOHM BW 151 (UL)

    Braking resistor, max. continous power: 300 W

    REOHM BW 151 (UL)
    • Resistance values: 10 - 300 Ohm
    • Continuous power: 50 - 250 W
    • max. operating voltage: 900 V

    Braking resistor for drives with frequency converters
    of low to medium power or as a charging resistor.
    Mounting close to the frequency inverter.



    • protection class IP 20 / IP 54

    • higher protection classes on request

    • test voltage 2.5 kV AC

    • other ratings and mounting dimensions on request

  • REOHM BW 151

    Braking resistor, max. continous power: 300 W

    REOHM BW 151
    • Resistance values: 10 - 300 Ohm
    • Continuous power: 50 - 250 W
    • max. operating voltage: 900 V

    Braking resistor for drives with frequency converters
    of low to medium power or as a charging resistor.
    Mounting close to the frequency inverter.



    • protection class IP 20 / IP 54

    • higher protection classes on request

    • test voltage 2.5 kV AC

    • other ratings and mounting dimensions on request

  • CNW 897

    Three-phase harmonic filter (400 V / 50/60 Hz)

    CNW 897
    • Nominal Voltage: 400 V
    • Rated current: 25 - 600 A
    • Inductance of the choke: 0.2 - 2.9 mH

    The filter is designed for the reduction of the THD (Total Harmonic Distortion) when used with B12 rectifiers. The harmonic currents are extremely suppressed so that the THD is reduced to lower than 5% (for example in UPS-systems)

    Typical values of Total Harmonic Distortion with B12 rectifiers and use of transformers are between 12 and 13%. This complies with the EN 61000-3-4 and EN 61000-3-12 standards.

    If more severe conditions for the mains are defined, in addition to the transformer it is necessary to use REO-Harmonic-Filter type CNW 897. These filters are available in two different versions:

    • THD < 5%
    • THD < 10%

    The IP00 version is especially suitable for panel mounting and can be mounted to save space here. The CNW 897 helps to comply with international power quality standards IEEE 519 or EN 61000-3.

    • Nominal voltage: 400V
    • Frequency: 50Hz
    • In accordance with: EN 60289 / EN 61558
    • Test voltage: L - L 2,500 V , DC 1s ; L - PE 2,500 V , DC 1s
    • Insulation class: T40 / F
    • Protection: IP 00 (also available as IP20 version )
    • Climate class: IEC 60068-1 DIN
    • Nominal voltage: 400V / 50 Hz
    • Standards: IEEE 519 , EN 61000-3-12 , EN 61000-3-2 , IEC 61000-3-4
  1. Page:
  2. 1
  3. 2

Downloads

  • Download
    UL-certificated Products
    pdf 4.00 KB

    UL-certificated Products

    REO - UL-certificated Products
    Download
  • Download
    Highest protection classes for REO Braking resistors
    pdf 4.00 KB

    Highest protection classes for REO Braking resistors

    for highest requirements
    Download
  • Download
    REO achieve highest IP protection ratings
    pdf 4.00 KB

    REO achieve highest IP protection ratings

    for safe use in aggressive environments
    Download
  • Download
    Performance wiith sinusoidal filters
    pdf 4.00 KB

    Performance wiith sinusoidal filters

    Save money with unshielded cables
    Download
  • Download
    Line Reactor CNW 9022
    pdf 4.00 KB

    Line Reactor CNW 9022

    CNW 9022 line reactor with integrated surge protection
    Download
  • Download
    Catalog - Drives
    pdf 4.00 KB

    Catalog - Drives

    IndustrialConverter Solutions - Drives
    Download
  • Download
    Current and voltage sensors Product catalogue
    pdf 4.00 KB

    Current and voltage sensors Product catalogue

    REO current and voltage sensors, Product catalogue
    Download
  • Download
    Liquid cooled systems catalog
    pdf 4.00 KB

    Liquid cooled systems catalog

    Product catalog for liquid cooled systems
    Download
  • Download
    Reactors and Filters overview
    pdf 4.00 KB

    Reactors and Filters overview

    The product range at a glance
    Download
  • Download
    REOWAVEpassive
    pdf 4.00 KB

    REOWAVEpassive

    The new generation of harmonic filters
    Download
  • Download
    Questionnaire water cooling
    pdf 4.00 KB

    Questionnaire water cooling

    Questionnaire water cooling
    Download
  • Download
    Operating instructions
    pdf 4.00 KB

    Operating instructions

    Operating instructions - REO - Mains chokes, DC chokes Motor chokes, sine-wave filters, du/dt chokes
    Download