us
PowerQuality Solutions

PowerQuality Solutions

POWER QUALITY - MORE THAN JUST THE COMPLIANCE OF EMC Directives

Presently electricity producers and suppliers are responsible for ensuring that the public supply conforms to the power quality standard EN 50160. However, it is in their own interest for electrical plant operators to minimize disruptions to the grid and so reduce production losses caused by system faults.

In addition to problems such as harmonics and voltage dips there is also the more important issue of saving energy to preserve our resources. REO follows a holistic approach, under the title of „Power Quality“, which considers the needs of both the nertwork and the consumers.

Thus, the core activity of REO AG is to find the very best solutions for maintaining the quality of our power supply.

Power Quality Solutions

Products such as Line filters and reactors, dv / dt filters and reactors, sinusoidal filters, regenerative filter and the harmonic filter REOWAVEPassive contribute not only to  prevent  disturbances, but  to save energy, too .

For example, by using a REOWAVE passive filter, up to 30 % energy savings can be achieved.

These are just some of the solutions that we offer in the field of power quality for you. In addition to power reactors, EMC and harmonic filters , we also offer customized solutions and services like EMC measurements - talk to us !

  • CNW 8981- 50 Hz

    REOWAVEpassive - harmonic filter 50 Hz/400V (IP00)

    CNW 8981- 50 Hz
    • Nominal Voltage: 400 V
    • Rated current: 6 - 1200 A
    • Frequency: 50 Hz

    Reduce Harmonics - save up to 30% energy costs.

     

     

    The REOWAVE®passive filters harmonics caused by the B6 circuit (thyristor, diode bridge, etc.) and motor drives. The supply network is relieved by compensating the harmonics reactive power. This enables cost savings in material selection and energy consumption. Starting currents and current peaks are greatly attenuated.

    This increases the service life and reliability of electrical systems.  Due to the compact and ready-build an easy installation is possible. 

    The REOWAVE®passive helps to comply with international power quality standards IEEE 519 or EN 61000-3.

    • Nominal voltage: 400V
    • Frequency: 50Hz
    • In accordance with: EN 60289 / EN 61558
    • Test voltage: L-L 2,500 V, DC 1min; L-PE 2,500 V, DC 1min
    • Insulation class: T40 / F
    • Climate class: IEC 60068-1 DIN
    • Protection: IP 20 (also available as IP00 version)
    • Nominal voltage: 400V / 50 Hz
    • Standards: IEEE 519, EN 61000-3-12, EN 61000-3-2, IEC 61000-3-4

     

  • CNW 903

    Three-phase line reactor 4% Uk

    CNW 903
    • Nominal Voltage: 3 x 500 V
    • Rated current: 3-1200 A
    • Inductance: 9.800-0.024 mH

    Power Noise Reduction - save up to 20% energy costs. A mains choker relieved the supply network by compensating the harmonics reactive power. The harmonics and commutation notches are reduced strongly. By using a mains choke the inverter electronics and DC-capacitors will be protected.

    Starting currents and current peaks are reduced up to 60%. Mains chokes help to comply with international power quality standards IEEE 519 or EN 61000-3-2.

    • Rated voltage: U ≤ 3 x 500 V 
    • Short circuit: Uk 4% (400VAC/50Hz, INenn)
    • Frequency: 50/60 Hz
    • According to: EN 60289 / EN 61558
    • Test voltage: L-L 2,500 V, DC 1min; L-PE 2,500 V, DC 1min
    • Insulation class: T40/F
    • Protection rating: IP00
    • Climatic category: DIN IEC 60068-1
    • Overload: 1.5 x INenn 1 min / h
    • Design: mounted on footprint

     

    Typical applications

    • Drive systems for motor drives:
      • Mechanical engineering
      • Elevators / escalators
      • Pipes
      • Conveyor technology
      • Ventilation and air conditioning
      • Robotics
      • Automation technology
    • Power supplies
    • Wind turbines


  • CNW 9022

    Line reactor with surge protection

    CNW 9022
    • Nominal Voltage: 230 V (DC) V
    • Rated current: 10 A / 16 A
    • Inductance: 2 x 1.46 +/- 10% / 2 x 0.92 +/-10% mH

    The CNW 9022 is designed to accommodate minimal spatial requirements, includes integrated surge protection.


    CNW 9022 line reactor with integrated surge protection smooths current peaks in controller input power, helping to maintain consistent product movement and extend equipment life. This filter has been specifically developed for use with vibratory feeder controllers to reduce stress on internal components and the power supply feeding the controller.


     


    Typical applications



    • use with vibratory feeder controllers to reduce stress on internal components and the power supply feeding the controller.


     

  • CNW 8981-50 Hz

    REOWAVEpassive - harmonic filter 50 Hz/400V (IP20)

    CNW 8981-50 Hz
    • Nominal Voltage: 400 V
    • Rated current: 6 - 1200 A
    • Frequency: 50 Hz

    Reduce Harmonics - save up to 30% energy costs.

    The REOWAVE®passive filters harmonics caused by the B6 circuit (thyristor, diode bridge, etc.) and motor drives. The supply network is relieved by compensating the harmonics reactive power. This enables cost savings in material selection and energy consumption. Starting currents and current peaks are greatly attenuated.

    This increases the service life and reliability of electrical systems.  Due to the compact and ready-build an easy installation is possible.

    The REOWAVE®passive helps to comply with international power quality standards IEEE 519 or EN 61000-3.

    •  Nominal voltage: 400V
    • Frequency: 50Hz
    • In accordance with: EN 60289 / EN 61558
    • Test voltage: L-L 2,500 V, DC 1min; L-PE 2,500 V, DC 1min
    • Insulation class: T40 / F
    • Climate class: IEC 60068-1 DIN
    • Protection: IP 20 (also available as IP00 version)
    • Nominal voltage: 400V / 50 Hz
    • Standards: IEEE 519, EN 61000-3-12, EN 61000-3-2, IEC 61000-3-4

     

  • CNW 957

    Regenerative harmonics filter (400V/50 Hz)

    CNW 957
    • Nominal Voltage: 400 V
    • Rated current: 14 - 74 A

    LCL filters are used especially in regenerative converters (AFE), but also for inverters for renewable energies. The main purpose of this filter is to eliminate the PWM frequencies for protect the supply network.

    • Rated voltage: 3 x 400V / 50Hz 
    • Climatic category: 25/085/21 DIN IEC 68 Part 1
    • Ambient temperature: 40°C
    • Protection rating: IP00
    • Optional: available with charging resistor


  • CNW 897

    Three-phase harmonic filter (400 V / 50/60 Hz)

    CNW 897
    • Nominal Voltage: 400 V
    • Rated current: 25 - 600 A
    • Inductance of the choke: 0.2 - 2.9 mH

    The filter is designed for the reduction of the THD (Total Harmonic Distortion) when used with B12 rectifiers. The harmonic currents are extremely suppressed so that the THD is reduced to lower than 5% (for example in UPS-systems)

    Typical values of Total Harmonic Distortion with B12 rectifiers and use of transformers are between 12 and 13%. This complies with the EN 61000-3-4 and EN 61000-3-12 standards.

    If more severe conditions for the mains are defined, in addition to the transformer it is necessary to use REO-Harmonic-Filter type CNW 897. These filters are available in two different versions:

    • THD < 5%
    • THD < 10%

    The IP00 version is especially suitable for panel mounting and can be mounted to save space here. The CNW 897 helps to comply with international power quality standards IEEE 519 or EN 61000-3.

    • Nominal voltage: 400V
    • Frequency: 50Hz
    • In accordance with: EN 60289 / EN 61558
    • Test voltage: L - L 2,500 V , DC 1s ; L - PE 2,500 V , DC 1s
    • Insulation class: T40 / F
    • Protection: IP 00 (also available as IP20 version )
    • Climate class: IEC 60068-1 DIN
    • Nominal voltage: 400V / 50 Hz
    • Standards: IEEE 519 , EN 61000-3-12 , EN 61000-3-2 , IEC 61000-3-4