Download PDF
Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOLOAD 101

REO Resistive load

REOLOAD 101

Unique Selling Point


  • Equipment can be controlled locally or via a PLC.
  • fine adjustment locally using motorized circular adjustment potentiometer or remotely via PLC
  • additional 24 VDC supply pro­vided for PLC control
  • transportable version and op­tion of connection via plug con­nectors or test lead sockets possible

Description


Applications:  These load units are designed for continuous operation and are used for endurance testing of converters and switch mode power supplies for railway applications.

  • Conform to VDE 0100
  • Test voltage:3 kV
  • Protection: IP 20
  • Ambient temperature: 40 °C

 

Features

  • 7 fixed resistor stages and a fine trimming stage
  • control by Ø 22 mm push-but­tons and switches
  • integral forced cooling and digital interface for external PLC con­trol with 24 V DC relay
  • Individual resistor stages can be switched in and out via contac­tors.

Technical Data


  • Voltage : 250 V
  • Current : 0.5 - 20 A
  • Resistance values : 7.4 - 1056 Ω

Connection diagram

 

Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOLOAD 101

REO Resistive load

Technical data

 

Type

Supply voltage
[V, AC]

Control voltage
[V]

Ohmic values
[Ω]

Current
[A]

REOLOAD

101

250

or rather 

150

with the 20 A-Stage 

50 / 60 Hz

230

430-1056

480

240

120

60

30

15

7.4

0.6

0.5

1.0

2.1

4.2

8.3

16.7

20

 

Control inputs: 24 V DC

Fine trim stage adjustment time: 35 secs for the full control range

Surface finish: RAL 7032

FA Cooling

 

Dimension drawing