CNW 897

Three-phase harmonic filter (400 V / 50/60 Hz)

CNW 897

Unique Selling Point


  • Reduction of the THDI value
  • Low voltage drop
  • Increasing network stability
  • Reduction of input current up to 30%
  • Suitable for installation in control cabinets
  • Easy integration into existing systems
  • Increased reliability of electrical installations

Description


The filter is designed for the reduction of the THD (Total Harmonic Distortion) when used with B12 rectifiers. The harmonic currents are extremely suppressed so that the THD is reduced to lower than 5% (for example in UPS-systems)

Typical values of Total Harmonic Distortion with B12 rectifiers and use of transformers are between 12 and 13%. This complies with the EN 61000-3-4 and EN 61000-3-12 standards.

If more severe conditions for the mains are defined, in addition to the transformer it is necessary to use REO-Harmonic-Filter type CNW 897. These filters are available in two different versions:

  • THD < 5%
  • THD < 10%

The IP00 version is especially suitable for panel mounting and can be mounted to save space here. The CNW 897 helps to comply with international power quality standards IEEE 519 or EN 61000-3.

  • Nominal voltage: 400V
  • Frequency: 50Hz
  • In accordance with: EN 60289 / EN 61558
  • Test voltage: L - L 2,500 V , DC 1s ; L - PE 2,500 V , DC 1s
  • Insulation class: T40 / F
  • Protection: IP 00 (also available as IP20 version )
  • Climate class: IEC 60068-1 DIN
  • Nominal voltage: 400V / 50 Hz
  • Standards: IEEE 519 , EN 61000-3-12 , EN 61000-3-2 , IEC 61000-3-4

Technical Data


  • Nominal Voltage : 400 V
  • Rated current : 25 - 600 A
  • Inductance of the choke : 0.2 - 2.9 mH

Circuit example


Typical applications:

  • Drive technology for motor drives, e.g:
  • Engineering
  • Elevators / escalators
  • Pipe
  • Conveyor Technology
  • Ventilation and air conditioning
  • Robotics
  • Automation Technology
  • Power Supplies
  • Failsafe processes
  • Applications with a 6- pulse rectifier
Your contact: +1 (317) 899-1395 • info@reo-usa.com

CNW 897

Three-phase harmonic filter (400 V / 50/60 Hz)

Technical data

Type

Rated
voltage/
Rated frequency
[V]

Rated
current
3x[A]

Inductance
3x[mH]

Capacity
capacitor[µF]

Rated power
[kVA]

Power loss
[W]

Cu / Al
[kg]
Weight choke
[kg]
Weight
capacitor [kg]
CNW 897/25/400/5%3 x 400
50/60 Hz
252.93 x 6817.3709 / 0205.98
CNW 897/40/400/5%402.483 x 8027.79011 / 0266.58
CNW 897/70/400/5%701.13 x 18048.513018 / 03210.18
CNW 897/90/400/5%900.93 x 22062.42000.8 / 3.44912.58
CNW 897/120/400/5%1200.753 x 220 + 3 x 4083.12500.8 / 5.15917.66
CNW 897/150/400/5%1500.63 x 330103.93501 / 8.45916.78
CNW 897/180/400/5%1800.53 x 220 + 3 x 180124.73301.1 / 8.46521.86
CNW 897/250/400/5%2500.363 x 330 + 3 x 220173.24401.7 / 12.88229.33
CNW 897/310/400/5%3100.36 x 330214.85701.9 / 149533.53
CNW 897/400/400/5%4000.2256 x 330 + 3 x 220277.19103 / 10.110845.2
CNW 897/600/400/5%6000.29 x 330415.71,0406.4 / 22.819349.4

THD < 10% on request

Your contact: +1 (317) 899-1395 • info@reo-usa.com

CNW 897

Three-phase harmonic filter (400 V / 50/60 Hz)

 

Dimensions drawings

 

Dimensions

TypeL
[mm]
B
[mm]
H
[mm]
N1
[mm]
N2
[mm]
ØD1
[mm]
A1
[mm]
ØD2
[mm]

Connection terminal/
Flat copper

CNW 897/25/400/5%2401062751858410 x 18--connection terminal 10 mm²
CNW 897/40/400/5%24012628518510410 x 18--connection terminal 16 mm²
CNW 897/70/400/5%3001233452249510 x 18--connection terminal35 mm²
CNW 897/90/400/5%30021126322416510 x 18339flat copper 25x3 mm
CNW 897/120/400/5%34020929324816510 x 18329flat copper 25x3 mm
CNW 897/150/400/5%36021729126416710 x 183711flat copper 30x3 mm
CNW 897/180/400/5%36021331126416710 x 183711flat copper 30x3 mm
CNW 897/250/400/5%42021536831616413 x 203911flat copper 30x4 mm
CNW 897/310/400/5%48021741435615813 x 203911flat copper 30x4 mm
CNW 897/400/400/5%42026636431620413 x 204913flat copper 40x5 mm
CNW 897/600/400/5%48031746635623813 x 205913flat copper 40x8 mm
Your contact: +1 (317) 899-1395 • info@reo-usa.com

CNW 897

Three-phase harmonic filter (400 V / 50/60 Hz)

 

Dimension drawings of the chassis

 

Dimensions of the chassis

TypeImageL
[mm]
B
[mm]
H
[mm]
N1
[mm]
N2
[mm]
N3
[mm]
N4
[mm]
ØD
[mm]
ConnectionFuse
CNW 897/25/400/5%150024221945050100-7M8NH00 25A
CNW 897/40/400/5%150024221945050100-7M8NH00 35A
CNW 897/70/400/5%150024228445050100-7M8NH00 63A
CNW 897/90/400/5%150024235945050100-7M8NH00 100A
CNW 897/120/400/5%2500392359450501001257M8NH00 100A
CNW 897/150/400/5%150024235845050100-7M8NH00 125A
CNW 897/180/400/5%2500392359450501001257M8NH00 160A
CNW 897/250/400/5%2500415359450501001257M10NH1 200A
CNW 897/310/400/5%2500415358450501001257M10NH1 250A
CNW 897/400/400/5%3500572359450501002757M10NH2 315A
CNW 897/600/400/5%3500572358450501002757M10NH2 355A