Download PDF
Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB MFS 268 IP20

IP 20, Frequency-control with automatic detection of the resonant frequency

REOVIB MFS 268 IP20

Unique Selling Point


  • REO frequency units are able to control a vibratory conveyor independently of the mains input frequency
  • Automatic search of the resonant frequency of the vibratory conveyor system (with additional vibration amplitude sensor) and option of regulating vibration amplitude – Able to regulate the vibration amplitude to maintain a constant feed rate irrespective of load or changes in the mechanical system
  • Can be supplied with field bus interfaces: ProfiNet, EtherNet/IP, EtherCAT, CAN-Bus, ProfiBus, DeviceNet and RS232
  • Optional versions available with UL/CSA accreditation
  • Conveyor frequencies adjustable between 5...300 Hz
  • Mains voltage compensation with constant vibration amplitude
  • All settings can be made using the integrated display
  • Sinusoidal output current
  • Can be used on 110 V or 240 V autom. Detection 
  • User settings can be stored
  • Fill level/overflow control 
  • Versions available in various protection classes and with various connection options
  • MFS 269 is available with AC output signal for use with permanent-magnet armature.

Description


Frequency converters in the REOVIB MFS 268 series for vibratory conveyor technology offer the option of operating the vibratory conveyor at an optimal vibration frequency for the material - completely independently of the frequency of the electrical mains supply. 

It is moreover possible, thanks to the system patented by REO, to determine the resonant frequency of the vibratory system automatically and to regulate the vibration amplitude to constant values.  In addition, various sensor and valve logic links can be programmed.  Devices can optionally be equipped with field bus interfaces, and are also available as versions with UL/CSA certification. 

Devices in the REOVIB MFS 268 series are available with a max. output current of 3A, 6A, 8A and 16 A as IP20 versions for installation in switch cabinets.

 

Suitable sensor:

SW 10 IP54 free leads

REOVIB SW in IP54 design with free leads e.g. SW 10

 

Technical Data


  • Output voltage : 0 - 100 / 0 - 205 V
  • Output Current : max 3 / 6 / 8 / 16 A
  • Input voltage auto detect : 110 / 230 V

ID numbers 

Description

Standard unit ID#

UL listed ID#

MFS 268 3A IP20

621605

621607

MFS 268 6A IP20

621612

621614

MFS 268 8A IP20

621624

621621

MFS 268 16A IP20

621109

621117

Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB MFS 268 IP20

IP 20, Frequency-control with automatic detection of the resonant frequency

Technical data 

Mains input

110 / 230V
 

Mains frequency

50 / 60 Hz +/- 3 Hz

Output voltage

0…100 V / 0…205 V

Output current

max. 3 A / 6 A / 8 A / 16 A

Vibration frequency

5…150 Hz (Optional 300 Hz)

Setpoint value

Display, Potentiometer,
0…10V, 0…20 mA

Status signal

Changeover relay 250 V, 1A

Ext. Enable  

24 V DC, Switch 

Valve output

24 V, 150 mA (Option)

Sensor supply

24 V DC

Setting Umin / Umax 

LED-Display

Soft start

Adjustable 0…5 sec.

Fill level/overflow control 

PNP, 24 V DC

Coarse/fine control

x

Vibration amplitude regulation

x

Resonant frequency search

x

Selectable timer function

x

Sensor time out monitor

x

Mains voltage compensation

x

Field bus interfaces

EtherNet/IP, EtherCat, DeviceNet, RS232,
CAN-Bus, Profibus-DP, DeviceNet

Standard Conformity

UL (Option), CE, RoHS

Protection class

IP20

Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB MFS 268 IP20

IP 20, Frequency-control with automatic detection of the resonant frequency

Available with numerous fieldbus interfaces (also with UL option):

   

REOVIB MFS 268 IP20

CAN bus interface (CAN)

Config. file CAN Bus (eds)

REOVIB MFS 268 IP20

DeviceNet  interface (DN)

Config. file DeviceNet (eds)

REOVIB MFS 268 IP20

EtherCAT  interface (EC)

Config. file EtherCat-V01 (xml)

Config. file EtherCat-V02 (xml)

REOVIB MFS 268 IP20

ProfiNet interface (PN)

Config. file Profinet-V01 (gsdml)

Config. file Profinet-V02 (gsdml)


Fieldbus interface

REOVIB MFS 268 IP20

Profibus interface (DP)

Config. file Profibus (gsd)

REOVIB MFS 268 IP20

EtherNet/IP interface (EIP)

Config. file EthernetIP (eds)

REOVIB MFS 268 IP20

RS232 interface (RS)

 

                                                             

Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB MFS 268 IP20

IP 20, Frequency-control with automatic detection of the resonant frequency

Dimension drawing IP 20 - 3A


Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB MFS 268 IP20

IP 20, Frequency-control with automatic detection of the resonant frequency

Dimension drawing IP 20 - 6A

Dimension drawing IP 20 - 8A

Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB MFS 268 IP20

IP 20, Frequency-control with automatic detection of the resonant frequency

Dimension drawing IP 20 - 16A

MFS 268 16A IP20 dimensions