Download PDF
Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB SWM 1000

Acceleration and amplitude sensor for vibratory systems

REOVIB SWM 1000

Unique Selling Point


  • Separate acceleration and amplitude measurements
  • Robust IP 65 housing
  • Interference free 0(4)... 20 mA signal

Description


Acceleration and amplitude sensor for vibratory systems. The sensor measures the amplitude of an electro-magnetic or motor -driven vibratory system and provides 0(4)...20 mA output signals for both acceleration and amplitude. The outputs from the sensor can be connected directly to a meter which has a 0(4)...20 mA input or used for monitoring e.g. conneted to a PLC.

Technical Data


  • Frequency range : 5...150 Hz

Input voltage

24 V, DC,   20...28 V. 2% Ripple

 

Output 1 measurement range
Acceleration

+/- 10 g   (0...20 g) ,  g=9.82 m/s Acceleration =Amplitude x 2
 

 

Output signal

0(4)...20 mA
 

 

Load resistor

2...750 Ohm
 

 

Output 2 measurement range
Amplitude

0...20 mm  (+/-10 mm),      Amplitude=Amplitude x 2
 

 

Output signal

0 (4)...20 mA
 

 

Load resistor

200...750 Ohm
 

 

Frequency range

5....150 Hz
 

 

Overload capacity

+/- 1000 g
 

 

Operating temperature

-10....+50 C
 

 

Cable length

5 m
 

 

Protection

IP 65
 

 

Dimensions

64 x 98 x 34 mm
 

 

Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB SWM 1000

Acceleration and amplitude sensor for vibratory systems

Connections

SWM 1000 connections

Your contact: +1 (317) 899-1395 • info@reo-usa.com

REOVIB SWM 1000

Acceleration and amplitude sensor for vibratory systems

Dimension Drawing

 SWM 1000 dimensions